Description:
20-1500ml (VCV); Applicable to adult, pediatric, infant
Various modes for different needs of all patients
Plug-in Anesthesia Agent, CO2, and SpO2 monitoring modules (optional)
15 inch TFT touch screen & big font view for easy observation
Touch screen & navigation knob for simple operation
Simultaneous display of 4 waveforms and 2 loops
Electronic flowmeters for O2, N2O, Air. High accuracy and easy reading
Highly integrated absorber, autoclavable in 134°C to avoid cross-infection (optional)
The absorber could be automatically heated, to avoid condensation water
Electronic PEEP
Advanced proportional solenoid technology to realize accurate ventilation control
Active AGSS system deal with exhaust gas and reduce pollution, providing more safety protection (optional)
Technical Specification:
Specification | Ventilation modes: VCV, PCV, SIMV(V)+ PS, SIMV(P)+PS, Sigh, Spont/CPAP, PRVC, Cardio Pulmonary Bypass, Standby, Manual |
Tidal Volume: 20-1500mL | |
Ventilation frequency: 1-100bpm | |
I:E: 4:1-1:10(increment: 0.5) | |
Ti: 0.1-10s(increment: 0.1s) | |
Inspiratory pause(Tp): OFF, 5%-50% | |
Flow Trigger: 1-15L/min | |
Pressure control: 5-70 cmH2O | |
Pressure support: 5-60 cmH2O | |
Pressure limited: PEEP+5-PEEP+ 70 cm H20 | |
Electronic PEEP: OFF, 4-30 cm H2O | |
Monitoring Volume: VTI, VTE, MV, MVspont Pressure: Ppeak, PEEP, Pplat, Pmean, Pmin Freq, Fspont, I:E, Compliance, Resistance, FiO2 SpO2 Module (optional): SpO2, PR (Plug-in) CO2 Module (optional): EtCO2, FiCO2 (Plug-in, Mainstream and Sidestream) Anesthetic Agent Module (optional): Anesthetic agent, N2O, CO2, MACAge and Agent Consumption (Plug-in, Mainstream and Sidestream) | |
Waveform: P-T, F-T, V-T, Optional: SpO2-T, CO2-T, FiO2-T, Anesthetic agent-T | |
Loop: P-V, F-V, F-P, Optional: Volume-CO2 | |
Trend: Ppeak, FiO2, MV, PEEP, VTE | |
Alarm: . Audio and visual alarms with three levels Volume: MV high/low, VTE high/low Pressure: Paw high/low, Negative pressure, Apnea Continuous high airway pressure, Low O2 supply pressure Freq high/low, FiO2 high/low, EtCO2 high/low (optional), SpO2 low (optional) Power: AC power failure, Low battery power, Exhausted battery failure | |
Vaporizer | 2 stations with interlock (Selectatec compatible) |
Agent type: Halothane, Enflurane, Isoflurane, Sevoflurane | |
Filler type: Pour fill, Quik fil(only Sevoflurane) | |
Pneumatic Specification | Gas supply: O2, N2O, Air: 0.28-0.6 Mpa |
Electronic Flowmeter: O2/N2O/Air: 0-l0L/Min | |
Gas system: O2 deficiency alarm. Hypoxic guard system, O2 flush: 35-75L/Min | |
Working mode: Closed, Semi-closed, Semi-open, Open | |
Driven mode: Pneumatically driven and electronically controlled | |
Operating mode: Manual/Vent; APL: 2-70 cmH20 | |
ACGO Connector: 22mm | |
Physical Specification | Dimensions (HxWxD): 1550*1000*870(mm) |
Communication Interface: VGA, RS232 | |
Screen: 15 inch TFT touch screen | |
Net weight: 108 kg | |
Power: 100-240VAC, 50/60Hz,6.5A(Max) | |
Lithium Battery: Minimum 120 minutes |