Home  >  Products  >  Hemodialysis System  >  Dialysis machine
CRRT Kidney Hemodialysis Machine for ICU
  • CRRT Kidney Hemodialysis Machine for ICU
CRRT Kidney Hemodialysis Machine for ICU

Get Quotes

Download Full Catalogue

CRRT Kidney Hemodialysis Machine for ICU

Product Parameters:

NO.Model NO.Description
1CNME-5000B
Four Pumps,
including one Heparin Pump, with two scales, 6 treatment modes(CVVHD, CVVH, SCUF, HP, PE, PA)
2CNME-5000AFive Pumps, including one Heparin Pump, with three scales, 7 treatment modes(CVVHD, CVVH, CVVHDF, SCUF, HP, PE, PA, RCA-regional citrate anticoagulation, Replacement fluid dual channel input)
3CNME-5000
Six Pumps,
including one Heparin Pump, with four scales, 14 treatment modes(CVVHD, CVVH, CVVHDF, SCUF, HP, PE, PA, CPFA, MARS, FPSA, SPAD, DFPP, RAD, PDF, RCA-regional citrate anticoagulation, Replacement fluid dual channel input)


Technical Parameter:

Basic Information


Dimension

Height 1720mm/Width 635mm/Thickness 578mm

Weight

About 75kg

Electrical Parameters

Voltage ~110/220V

Frequency 50/60Hz

Power 500VA

Backup Battery Capacity 2*12V/4AH

Pressure Monitoring


Venous Pressure Monitoring(Vp)

-500mmHg~+700mmHg Accuracy: ±5mmHg

Arterial Pressure Monitoring(Ap)

-500mmHg~+700mmHg Accuracy: ±5mmHg

Transmembrane Pressure Monitoring(Tmp)

-500mmHg~+700mmHg Accuracy: ±5mmHg

Primary Membrane External Pressure Monitoring(Pm1)

-500mmHg~+700mmHg Accuracy: ±5mmHg

Secondary Membrane Pressure Monitoring(Pm2)

-500mmHg~+700mmHg Accuracy: ±5mmHg

Liquid Balance Control


Scale Number

4

Rehydration Scale

0kg~30kg Accuracy: ±5g or ±0.1%

Waste Liquid Scale

0kg~30kg Accuracy: ±5g or ±0.1%

Auxiliary Rehydration Scale I

0kg~12kg Accuracy: ±5g or ±0.1%

Auxiliary Rehydration Scale I

0kg~12kg Accuracy: ±5g or ±0.1%

Flow Monitoring


Blood pump flow(BP)

0mL/min, 30mL/min~600mL/min

Accuracy: set value±10%

LP1

0mL/min, 1mL/min~250mL/min

Accuracy: ±0.1mL/min or ±5% of set value

Waste Liquid Pump Flow(UFP)

0mL/min, 1mL/min~250mL/min

Accuracy: ±0.1mL/min or ±5% of set value

LP2

0mL/min, 1mL/min~250mL/min

Accuracy: ±0.1mL/min or ±5% of set value

Function Pump Flow(FP)

0mL/min, 1mL/min~250mL/min

Accuracy: ±0.1mL/min or ±5% of set value

Infusion pump flow

Flow Adjustable Range: 0mL/h~10mL/h

Error Range: ±0.2mL/h

Rapid Injection Flow: 10mL/h~2000mL/h

Syringe Specification: 10mL/20mL/30mL/50mL

Dehydration Error

≤±20mL/h

Liquid Balance Control

≤100mL

Substitution fluid flow temperature control


Control Range

33℃~40℃

Accuracy

Control error±1℃

Safety Monitoring


Blood Leakage Monitoring

≤0.35mL/min(HCT32%)

Air Monitoring

>0.02mL bubbles


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online