Home  >  Products  >  Emergency and Clinics Apparatuses  >  Electrosurgical Unit
High Frequency Electrotome Operation Gynaecology Leep Knife Unit for Surgical
  • High Frequency Electrotome Operation Gynaecology Leep Knife Unit for Surgical
  • High Frequency Electrotome Operation Gynaecology Leep Knife Unit for Surgical
  • High Frequency Electrotome Operation Gynaecology Leep Knife Unit for Surgical
  • High Frequency Electrotome Operation Gynaecology Leep Knife Unit for Surgical
  • High Frequency Electrotome Operation Gynaecology Leep Knife Unit for Surgical
High Frequency Electrotome Operation Gynaecology Leep Knife Unit for SurgicalHigh Frequency Electrotome Operation Gynaecology Leep Knife Unit for SurgicalHigh Frequency Electrotome Operation Gynaecology Leep Knife Unit for SurgicalHigh Frequency Electrotome Operation Gynaecology Leep Knife Unit for SurgicalHigh Frequency Electrotome Operation Gynaecology Leep Knife Unit for Surgical

Get Quotes

Download Full Catalogue

High Frequency Electrotome Operation Gynaecology Leep Knife Unit for Surgical

Model:CNME011112A-leep


Applicable to:


obstetrics and gynecology (cutting,hemostasis,cauliflower, cervical erosion,LEEP,all kinds of laparoscopic operations with laparoscopy,various gynecologic operations)


LEEP operation superiority:


The use of LEEP for gynecologic uterine lesions has improved the accuracy,controllability and safety of the operation.
It can be applied to the treatment of various diseases in obstetrics and gynecology (cutting,hemostasis,cauliflower, cervical erosion,LEEP,all kinds of laparoscopic operations with laparoscopy,various gynecologic operations)simplifying the
procedure,reducing the cost of the operation and improving the safety of the operation.
Many kinds of knife heads are suitable for cervical conization and vulva management, no carbonization and no pathological changes.
Spherical electrodes can be used for hemostasis,not focus blood vessels,do not damage nearby tissues,and recover faster after operation.
Needle shaped electrodes can be used for fine cutting.
Different thickness electrodes have different hemostatic effects.


Functional characteristics:


With memory function, the power setting value was used last time.

The neutral electrode contact quality monitoring circuit can detect the contact areabetween the electrode plate and the patient.
Both single and bipolar plates can be used.
High clear and large digital display.
This machine has automatic detection function and error code prompts.


Output Characteristics of Loop Electrosurgical Excision Procedure:

Working modeMaximum Power(Watts)Rated Load
Monopolar CutCutting200W500Ω
Blend 1150W500Ω
Blend 2100W500Ω
Monopolar CoagCoag 1100W500Ω
Coag 280W500Ω
Bipolar CoagStandard Coag 50W200Ω


Technical Specifications of Loop Electrosurgical Excision Procedure:


Working frequency: 360-460 kHz
Atmospheric pressure range:86.0-106.0 kpa
Power supply:220V(+22V), 50Hz(+1)
Rated power of equipment:880 VA+10%
Power consumption:≤1000VA


The technical parameters of the smoking device(Integrated with trolley):


Maximum flow:0-200L/min(adjustable suction force)

Absorption efficiency:>95%
Noise level: maximum 40dB
Power supply voltage:110V-220V, 50/60Hz
Absorption of flow rate:200L/min


Standard packing list:

Mainframe 1 set
Smoking device1 set
Medical cart1 set
Electrosurgical pencil5 pieces
Vaginal dilator 1 piece
Smoke exhaust pipe2 pieces
Smoke filter element1 piece
Silicone hose1 piece
Induction loop1 piece
Neutral electrode10 pieces
Neutral electrode cable1 piece
Foot switch1 set
Bipolar tweezers with cable1 piece
Electrode10 pieces


Parameter comparison:

Model

CNME011112A-leep

CNME011112B-leep

CNME0111RF-1

CNME0111RF-3

CNME011105

Maximum Power

Monopolar:200W  

Bipolar:50W

Monopolar:200W 

Bipolar:50W

Monopolar:100W

Monopolar:100W  

Bipolar:75W

Monopolar:100W  

Bipolar:50W

Applicable Surgeries

Gynecological Surgery

 

Gynecological Surgery

Gynecology surgery, Dentistry surgery, Anorectal surgery

Plastic (Cosmetic) surgery,Otorhinolaryngology (ENT) surgery,ophthalmology surgery

 

Dermatology, Dentistry, Plastic surgery

Working Mode

①Pure cut,②Blend cut 1,③Blend cut 2,④Soft Coag,⑤Strong Coag,⑥Bipolar Coag

 

①Pure cut,②Blend cut,③Soft Coag,④Strong Coag: 80W,⑤Bipolar Coag

①Pure cut,②Blend cut,③Spray coag,④Fulguration coag,⑤Spray coag

①Pure cut,②Blend cut,③Spray coag,④Fulguration coag,⑤Spray coag,⑥ Bipolar coag.

 

①Pure cut,②Blend cut,③Contact Coag,④Bipolar Coag

Advantages

The smoker is designed independently and can be used with other electrosurgical units

Integrated trolley with built-in smoking device

Radiofrequency Electrosurgical Unit,Monopolar mode - 4.00MHz