Home  >  Products  >  Emergency and Clinics Apparatuses  >  Patient Monitor
10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor
  • 10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor
  • 10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor
  • 10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor
  • 10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor
  • 10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor
10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor

Get Quotes

Download Full Catalogue

10.4” /12.1” Color LCD Screen ICU Multi Parameter Patient Monitor

Model:CNME010131/CNME010131plus


Features:

CNME010131:10.4" color LCD screen

CNME010131plus:12.1" color LCD screen

Backlight buttons

Multiple display modes optional: Standard interface,Big font, ECG standard full display,OXY,Trend table,BP trend,Viewbed

Ambulatory blood pressure technology, anti-movement

Special design against high frequency surgical unit,and defibrillation protection

Support SpO2-authorization partner

13 kinds of arrhymia analysis

15 kinds of drug dose calculation

Various languages operating systems

Built-in detachable rechargeable lithium battery 4hours battery life

To connect CMS, other bed observation and software updating with wireless and wired mode


Specifications:

ECG
Number of Leads3 or 5 leads(optional 12leads)
User SelectableI,II,III,aVR,aVL,aVFV(5 Lead);l,ll,III or(3 lead)
Gain Selectionx1/4,x1/2,x1 and x2
Frequency ResponseDiagnostic:0.05 to 130HZ
Monitor:0.5to40HZ
Surgery:1-20HZ
Heart rateAdult:15-300bpm/min
Neonate/Ped:15-350bpm/min
Accuracy±1% or ±1bpm
Diagnostic Mode>90 dB
Monitor Mode>100dB
Surgery Mode>100dB
ECG Signal Range±8mV(p-p)
Arrhythmia detectionAvailable
Arrhythmia analysis13species
Heart Rate
Source User SelectableSmart,ECG,Pleth
RangeAdult:30-250 bpm
Neonate/Ped:15-350bpm
Accuracy±1bpm or ±1% whichever is greater
Pulse Oximetry SpO2
Range0 to 100%
Resolution±3
Accuracy70% to 100% range±2%
0 to 69%; undefined
Respiration Rate
RateAdult:7~120rpm
Neo/Ped:7~150rpm
Resolution1Brpm
Accuracy±2Brpm
Apnea alarm10-40s
NIBP
TechniqueOscillometric during inflation
Cycles(Selectable)1,2,3,5,10,15,30,60,90,90,120,180,240,480min
Adult rangeSYS:40-270mmHg
DIA:10-215mmHg
MEAN:20-235mmHg
Pediatric rangeSYS:40-200mmHg
DIA:10-150mmHg
MEAN:20-165mmHg
Neonate RangeSYS:40-135mmHg
DIA:10-100mmHg
MEAN:20-110mmHg
NIBP Storage800group
STAT model5 minutes of continuous reading
Resolution1mmHg
Maximum Mean error accuracy±5mmHg
Maximum Standard Deviationaccuracy8mmHg
OverPresure protectionAdult: 300mmHg
Pediatric: 240 mmHg
Neonate: 150 mmHg
EtCo2
Range0-19.7% or 0-150mmHg or 0-20kPa
Resolution0.1mmHg
Accuracy0-40mmHg ±2mmHg
41-70mmHg ±5% of reading
71-100mmHg ±8% of reading
101-150mmHg ±10% of reading
Balancing gasenvironmental,NO2,He


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online