Scope Of Application
Ethylene oxide sterilizer cabinets are used for the sterilization of articles that are not resistant to high temperatures, moisture, and difficult to penetrate.
EO has a wide range of clinical applications, and equipment used in EO sterilization includes:
Hard and soft endoscopy,Medical equipment,Instruments,Rubber products,Plastic products.
Specification:
Product name | Vertical Ethylene Oxide Sterilizer |
Model | CNME060352 |
Capacity | 80L |
Chamber Size | 585*275*422mm |
Voltage | AC 220V 50HZ |
Material | 304 stainless steel |
Sterilization room material | 304 anti-corrosion stainless steel |
Temperature display | LCD touch screen |
Outer box material | Carbon steel (thickness 1.8mm) baking powder |
Power | 2.6KVA |
Power supply | AC220V,50Hz |
Sterilization Temperature | 50℃ |
Sterilization Pressure | -60kpa |
Sterilization Humidity | 45%-75% |
Sterilization Time | 0-99 hours adjustable |
Heating method | Electric heating |
Dimension | 795*615*1140mm |
Equipment size(L×W×H) | 795×615×1140mm |
Inner diameter size(L×W×H) | 585×275×422mm |
Choose Gas | Pure ethylene oxide gas |
Vacuum speed | 15 minutes to pump to -60kpa |
Vacuum system | Use an oil-free vacuum pump |
Net Weight | 110 KG |
Package | Wood Case |
Vertical EO Sterilizer Components Features:
1.Make of high quality 304 stainless steel material
2.Fully automatic control system, Automatic ventilation, cycle ventilation 5 times, once every 15 minutes
3.Automatic ventilation, cycle ventilation 5 times, once every 15 minutes
4.Use a micro printer to print out the data every minute during the entire sterilization process, which can be stored permanently.
5.Sealed door using 5052 high-quality aviation aluminum, thickness ≥15mm, pressure resistance 200Kpa.
6.Automatic dosing - Built-in piercing technology in the sterilization chamber.
7.With over-voltage and over-temperature protection function, it is safer and more reliable.
8.Power-off memory function - If the power is cut off during the sterilization process, the screen will prompt "Yes" and "No" to continue the previous operation after the power is turned on again. At this time, you can select "Yes" to continue the last run. You can also choose "No" to cancel the operation.
9.Efficient analysis - The inefficient traditional analysis mode is changed. The steam degradation analysis method is adopted for the first time in China. The analysis time is short and the residue is far lower than the corresponding national standards.