Syringe Pumps: Precision in Medication Delivery

Syringe pumps are advanced medical devices ensuring controlled delivery of liquid medications or nutrients through intravenous or subcutaneous routes. They enhance precision, reduce errors, and ensure treatment efficacy, making them indispensable for critical scenarios requiring accurate drug delivery.

Equipment Categories

3 1 12s

CNME010512S

Single-Channel Syringe Pumps

3.5” color touch screen

Rate range 0.1~2000ml/h

Accuracy ±2%

Syringes: 5/6ml, 10ml, 20ml, 30ml, 50ml/60ml.

7 modes (rate, preset time, time rate, dose calculation, first dose, gradient, intermittent, sequence.)

Drug library; History records; Lithium battery

Positioning high-end, 7 injection modes, optional advanced TIVA mode

3 2 sh01

CNME0105SH01

Single-Channel Syringe Pumps

3.5” TFT color LCD

Rate range 0.1-1200 ml/h

Accuracy ±2%

Syringes: 5ml, 10ml, 20ml, 30ml, 50ml/60ml.

5 modes (Constant, time/volume, drug weight, micro, programmable)

Drug library; Lithium battery

3 3 s3

CNME0105C-S3

Single-Channel Syringe Pumps

3.5” color touch screen

Rate range 0.1-1500ml/h

Accuracy ±2%

Modes: Rate, Rate-Time, Rate-VTBI

Cost-effective basics with a price advantage

3 4 sh02

CNME0105SH02

Dual-Channel Syringe Pumps

5.0” TFT color LCD

Rate range 0.1-1200 ml/h

Accuracy ±3%

Syringes: 5ml, 10ml, 20ml, 30ml, 50ml/60ml.

5 modes (Constant, time/volume, drug weight, micro, programmable)

Drug library; Lithium battery

Supports simultaneous infusion of two drugs with independent control between channels

How to choose the right syringe pump

3 1 Accuracy And Flow Range

Accuracy and flow range

Flow Range: Syringe pumps need to be selected to ensure that their flow range meets clinical needs, especially in critical care and precision therapy.

Accuracy: Syringe pumps need to provide highly accurate flow control, especially critical in the infusion of low-dose drugs.

Types and doses of drugs supported

Type Of Drug: Choose a device that can support multiple drug infusions to meet different treatment needs, such as anesthetics and insulin.

Dose Adaptation: The device should have precise dose control, especially for children or special patient groups.

4 2 Types And Doses Of Drugs 2
3 3 Sensitivity Of The Alarm Function

Sensitivity of the alarm function

Alarm Type: The syringe pump needs to be equipped with alarm functions such as blockage, air bubbles, infusion rate deviation, etc. to ensure the safety of treatment.

Adjustability: Alarm thresholds should be adjustable on demand with distinct audible and visual cues.

Usage & Maintenance Recommendations

5 1

Daily Checks

Regular calibration, cleaning, and disinfection to ensure hygiene and functionality.

5 2 unknown 3

Operator Training

Comprehensive training to prevent errors and enhance response to alarms.

5 3 unknown scaled

Routine Maintenance

Monthly inspections, consumable replacements, and failure records to ensure reliability.

Submit Your
Medical Equipment Request

Submit Your Inquiry to CNMEDITECH,

All the Inquiries Will Be Replied Within 12 Hours.

We will send the catalog to your email.