Model:CNME010504
Features:
Parameter setting and editing directly on touch screen.
Using any standard IV sets and storing up to 200 editable brands.
Resetting rate, volume, air level, occlusion level without stop infusion.
5 infusion modes + Micro mode control.
Infusion rates range from 0.1ml/h to 2000ml/h.
Optional WIFI connection to central monitor.
Last therapy for rapid infusion start.
Specifications:
|
Case Material | PBT+PC |
Screen | 4.3 inch LCD color touch screen |
Infusion Mode | ml/h (include Rate mode, Time mode), Body weight, Drip, Sequence, Drug Library, Micro |
Accuracy | ±5% |
Flow Rate Range | 0.1-2000ml/h (min. increment 0.01 ml/h) |
VTBI | 0-9999.99 ml |
KVO | 0-5ml/h adjustable (min. increment 0.01 ml/h) |
Bolus Rate | 0.1-2000ml/h (automatic & manual bolus available) |
Occlusion Level | 5 levels selectable (50mmHg - 900mmHg) |
Interface | DB15 muti-functional interface |
Wireless | WiFi (optional) |
Alarm Type | VTBI Infused, Occlusion, Pressure drop, Battery empty, KVO finished, Standby time end, Door Open, Single air bubble, Accumulated air bubble, Abnormal drip rate, Empty drip chamber, VTBI near end,Battery near empty, Reminder alarm, No power supply, Drop sensor connection, System error, etc.
|
|
Titration | Change flow rate without stopping infusion |
Reset total volume | Reset total infused volume to zero without stopping infusion |
Reset occlusion level | Reset occlusion alarm level without stopping infusion |
Reset air bubble level | Reset air bubble alarm level without stopping infusion |
Last Therapy | Last therapies can be stored and used for rapid infusion |
Drug Library | No less than 2000 drugs |
DERS | Drug erro reduction system |
Anti-Bolus | Automatic drop line pressure to reduce bolus impact after occlusion |
Purge | Remove the air bubble |
Screen Lock | Avoid misoperation |
Standby Mode | Standby time adjustable |
Micro Mode | Limit the max infusion rate to double ensure patient safety |
DPS | Real-time pressure display in graphically and numerically |
Bubble Detector | Adjustable. Single bubble and accumulated bubble in 15min |
Brightness | Adjustable |
Alarm Volume | Adjustable |
History Record | More than 5000 entries |
|
AC Power | 110V-240V, 50/60HZ |
External DC Power | 10-16V |
Battery | Lithium Polymer battery 2600mAh*1, more than 5 hours operating time at 25ml/h Lithium Polymer battery 2600mAh*2, more than 10 hours operating time at 25ml/h |
|
Classification | Class I, CF |
Standard | CE; EN1789:2014 (Ambulance) |
Waterproof | IP44 |
Dimension | 138(L)*131.5(W)*90(H) mm |
Weight | Approx. 1.5KG (Pole clamp included) |