Home  >  Products  >  Emergency and Clinics Apparatuses  >  Syringe Pump and Infusion Pump
Automatic Intravenous Infusion Pump with Multiple Infusion Modes
  • Automatic Intravenous Infusion Pump with Multiple Infusion Modes
  • Automatic Intravenous Infusion Pump with Multiple Infusion Modes
  • Automatic Intravenous Infusion Pump with Multiple Infusion Modes
Automatic Intravenous Infusion Pump with Multiple Infusion ModesAutomatic Intravenous Infusion Pump with Multiple Infusion ModesAutomatic Intravenous Infusion Pump with Multiple Infusion Modes

Get Quotes

Download Full Catalogue

Automatic Intravenous Infusion Pump with Multiple Infusion Modes

Model: CNME010508



Features:
History records
Various infusion modes to meet different clinical requirements
KVO, Bolus and Anti-bolus
Anti-reverse rotation detection
Various visual and audible alarms
Drop sensor (optional)
Real time display
Compact and light weight design
Soft key design easy for operation
Free-flow protection
Double CPU ensuring safe infusion
Removable pump body, convenient for cleaning

 

Technical Specification:

Product name 

Automatic Micro Volumetric Intravenous Infusion Pump

Infusion rate

0.1-1200ml/h

Infusion accuracy

±5%

Applicable infusion set

Various brands of standard infusion set

Volume to be infused (VTBI)

0-9999(ml)

Volume infused

0-36000(ml)

KVO rate

1-5ml/h

Bolus rate

300-1200ml/h

Infusion mode

Rate mode

Drip mode

Purge rate

600ml/h

Air bubble detection

Ultrasound sensor detection with four levels of air in line alarm

Occlusion pressure

(40.0-160.0) KPa 3 adjustable occlusion pressure: low-middle(default)-high

Alarm

Use battery, Door open, Occlusion, Almost done, Forget operation, Infusion completion, Low Battery, Battery exhausted, malfunction etc.





Function




 

Anti-bolus (diminishes the unwanted volume of Bolus after removal of occlusion)

Ultrasound sensor detection with four levels of air in line alarm adjustable

Intelligent pressure detection alarm

Anti-reverse detection

History records and can be transferred to computer

Screen simultaneously display the infusion rate, drip rate, VTBI, volume infused, real time etc.

Bolus

Adjustable buzzer volume

KVO

Removable pump body for easy cleaning

Power supply

DC:12±1.2V AC:100~240V, 50/60HZ

Battery

Rechargeable Li_Polymer battery, 7.4V 1900mAh

Battery charging time

10 hours with power on,3 hours with power off

Battery operating time

About 6 hours at25ml/h

Power consumption

25VA




Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products