Home  >  Products  >  Emergency and Clinics Apparatuses  >  Ventilator
Breathing Apparatus Portable ICU Ventilator with Air Compressor
  • Breathing Apparatus Portable ICU Ventilator with Air Compressor
Breathing Apparatus Portable ICU Ventilator with Air Compressor

Get Quotes

Download Full Catalogue

Breathing Apparatus Portable ICU Ventilator with Air Compressor

Model: CNME010422

Features:

Multiple ventilation modes, suitable for ICU, emergency department and operation room etc: (PRVC, APRV, DUOLEVEL, V SIMV, P SIMV, IPPV, A/C, PCV, PSV, SPONT/CPAP, SIGH, MANUAL).

Pressure and flow dual triggering mechanism make patient breathe better and more comfortable.

Rapid oxygen supply, automatically offer high flow rate oxygen within two minutes.

Pressure-Time, Flow-Time, Volume Time, ETCO2-Timeosillogram, real-time display the condition of patient in all respects.

Separate design of electronic circuit and gas flow rate keep safe running of ventilator.

Compact long life internal battery can provide emergency power, avoid risk of patient.

3 level alarming system display overall condition of machine, easier for users to find and solve problems according to indication.

Oscillogram freezing and recovery offer doctors a better understanding of the real-time situation for patient.

Self-check before operation, ensure every port of machine is in good condition.


Technical Specification:

Ventilation Mode

PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV, IPPV, A/C, PCV, PSV, SPONT/CPAP, SIGH, MANUAL

Ventilator parameter

Tidal volume (Vt): 20 ~ 2000 mL

Frequency (Freq): 1min~100min

Oxygen concentration: 21%~100%

I:E: 4:1~1:8

PEEP: 0cmH2O ~ 40 cmH2O

Pressure limit: 20 cmH2O ~ 100 cmH2O

Monitoring parameter

Frequency (Freq): 0/ min~ 100/ min

Tidal volume(Vt): 20mL~2500mL

MV: 0 L/min ~ 99 L/min

Airway pressure: 0 cmH2O ~ 100 cmH2O

Dynamic lung compliance monitoring: 1mL/cmH2O ~ 1000mL /cmH2O

ETCO2 Concentration: 0mmHg ~ 152mmHg (0%-20%)

Oxygen concentration: 15%~100%

Oscillogram

P-T(Pressure-Time), F-T(Flow-Time), V-T(Volume-Time)

ETCO2-T (End-Tidal CO2 -Time)

P-V Loop(Pressure-Volume Loop), F-V Loop(Flow-Volume Loop), P-F Loop(Pressure- Flow Loop)

Alarm and protection

The AC power failure alarm: Power failure or no connection

Internal backup battery low voltage alarm≤11.3±0.3V

No tidal volume: No tidal volume within 6 s

High minute volume alarm: 5 L/min ~ 99 L/min

Low minute volume alarm: 1 L/min~ 30 L/min

High airway pressure alarm: 20 cmH2O ~ 100 cmH2O

Low airway pressure alarm: 0 cmH2O ~ 20 cmH2O

High oxygen concentration alarm: 19%~100%

Low oxygen concentration alarm: 18%~99%

Continuous pressure alarm: (PEEP+ 1.5 cmH2O)over16s

Suffocation warning: 5~ 60s

Fan error: Show on screen

Oxygen deficit: Show on screen

The maximum limited pressure: <12.5kPa

Working condition

Gas source: O2, Air

Pressure: 280 kPa- 600 kPa

Voltage: 220V±22V

Power frequency: 50Hz±1 Hz

Input power: 900 VA (With air compressor)

250 VA (Without air compressor)

Wooden case packing size

Main engine: 506*566*615 mm

G.W..43 KG, NW.: 22 KG

Air compressor: 683*687 * 1140 mm

G.W. : 105 KG, N.W.:70 KG .


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online