Get Quotes
Download Full Catalogue
Model:CNME01S24series
Description:
CNME01S24series High Flow Oxygen Therapy, can be used for patients with spontaneous breathing, including artificial airway respiratory insufficiency, and can be used for patients in hospitals and long-term care institutions.
CNME01S24series high-flow oxygen therapy, highly integrated design, to meet more needs of clinical treatment.Provide a maximum of 80L / min air-oxygen mixed gas, oxygen concentration can be set automatically.
Disinfection-free design, Water chamber has a backflow prevention valve to prevent gas backflow, and overall maintenance is more convenient.
Specifications:
Model | CNME01S24A | CNME01S24B |
Adjustment method of oxygen concentration | Manual | Auto |
Flow | Monitorable, adjustable | Monitorable, adjustable |
Flow range | 2L ~ 80L/min | 2L ~ 80L/min |
Oxygen concentration adjustment range | 21% ~ 100% | 21% ~ 100% |
Temperature output range | 29℃ ~ 37℃ | 29℃ ~ 37℃ |
Temperature adjustment gear | 9 steps adjustable | 9 steps adjustable |
Disinfection-free conception | Yes | Yes |
Screen size | 3.5 inches | 3.5 inches |
Trend review function | 1 day; 3 days; 7 days | 1 day; 3 days; 7 days |
Oxygen concentration | Monitorable | Monitorable, adjustable |
Temperature | Monitorable, adjustable | Monitorable, adjustable |
sPEEP | Monitorable | Monitorable |
Respiratory rate | Monitorable | Monitorable |
Automatic reminder of filter replacement | Yes, settable | Yes, settable |
Automatic water filling function | Yes | Yes |
Humidity compensation | -3~+3, 7 steps adjustable | -3~+3, 7 steps adjustable |
Warm standby | Yes | Yes |
Features:
1.Can set target oxygen concentration, temperature and flow
Control target oxygen concentration automatically, oxygen delivery in the machine, 21% -100%, accurate to 1%;
Wall oxygen source, oxygen cylinder, oxygen generator can support it;
The built-in ultrasonic oxygen sensor requires no maintenance.
9-stage humidification temperature: 29 ℃ -37 ℃, accurate to 1 ℃.
Advanced dual fan design, two levels of HFlow and LFlow, 2 L / min ~ 80 L / min, can meet patients of most ages.
Innovative 7-level humidity compensation function, providing ± 3 adjustable humidity compensation, easily coping with various harsh temperature and humidity environments
2.Warm standby function designed for convenient use and saving oxygen
CNME01S24series has a Warm standby function, which allows you to continue warm oxygen therapy at any time without turning off the machine for a short time to leave, saving oxygen without having to wait for warm-up time.
3.More comprehensive monitoring indexes
Real-time monitoring of Oxygen Concentration, Flow, Temperature, Respiratory Rate, sPEEP.
4.Simple installation and easy setup
Integration, disinfection-free design, saving clinical use and maintenance time.
Packaging details:
Main unit:44*39*37cm,6kgs/6.5kgs
Trolley:75*50*24cm/8.5kgs/10kgs