Get Quotes
Download Full Catalogue
Model:CNME01S21series
Product Description:
High flow heated respiratory humidifiers is mainly used to provide humidified and heated air-O2 mixed gas to the nasal cavity directly through a nasal congestion catheter without sealing,which is higher than the peak inspiratory flow rate of the patient. The oxygen concentration is accurate and adjustable, which makes the breathing more comfortable . It is an effective respiratory therapy that is suitable for invasive or non-invasive patients with spontaneous breathing, not for life support.
Applicable Department:
Respiratory medicine, ICU, Emergency room, Neurology, Neurosurgery, Cardiothoracic surgery, Paediatrics (≥3 kg), Rehabilitation ward, Geriatric ward, etc.
Performance Parameter:
Functional items | Models | |||
CNME01S21A | CNME01S21B | CNME01S21C | ||
O2 contro | Measurement of O2 concentration | ●
| ●
| ●
|
O2 Limit alarm | ●
| ●
| ●
| |
Settable range | 21%-100% | 21%-100% | - | |
Oxygen Accuracy | ±5% | ±5% | - | |
O2-Air Control mode | Software | Software | Buoy flowmeter control | |
Flow control function | Settable range | 2-80L/min | 2-70L/min | 2-60L/min |
Flow Accuracy | ±5L/min(High flow mode:25L/min~80L/min) ±2L/min(Low flow mode:2L/min~25L/min) | |||
Measurement | ●
| ●
| ●
| |
Temperature control function | Settable range | 31℃~37℃ / 7 levels | 31℃~37℃ / 7 levels | 31℃~37℃ 7 levels |
Temperature Accuracy | ±2℃ | ±2℃ | ±2℃ | |
Measurement | ●
| ●
| ●
| |
Review function | History Review | ●
| ●
| ●
|
Timing function | Accumulated therapy time | ●
| ●
| ●
|
Total use time | ●
| ●
| ●
| |
Preset signal therapy duration | ●
| ●
| ●
| |
Night Mode | ●
| ●
| ●
| |
Physical and Electrical | IP Classification | IPX0 | ||
Dimensions | 336mm × 233mm × 136mm | |||
Weight | 3.2kg | |||
Power input | AC 220V,2A Max, 50Hz | |||
Note: ●indicates with this configuration; — indicates no such configuration. |
Clinical characteristics:
Maintain optimal humidity in combination with a nasal congestion catheter to ensure the comfortable delivery of high-flow mixed oxygen gas to achieve the following therapeutic effects:
1.Auxiliary oxygen:
Maintain a stable high inhaled gas oxygen concentration,improve oxygenation, reduce blood oxygen deficiency, and increase effective alveolar ventilation.
2.Positive airway pressure:
Produce low end-expiratory positive pressure (PEEP),reduce breathing power consumption, improve breathing frequency;promote alveolar opening, conducive to the diffusion of oxygen.
3.Reduce dead space:
Reduce the dead space of mouth, nose and pharynx, promote the conversion of oxygen and improve ventilation efficiency.
4.Airway humidification:
Reduce the dead space of mouth, nose and pharynx, promote the conversion of oxygen and improve ventilation efficiency.
Performance Advantages:
1.Precise oxygen concentration control and monitoring
The oxygen concentration setting range is 21% to 100%. Ultra-sensitive oxygen concentration sensor and miniature proportional valve can accurately control the oxygen concentration to ensure that the mixed gas can meet any oxygen concentration requirements of patients. At the same time, the oxygen concentration can be monitored in real time to ensure that the oxygen concentration is accurate and effective.
2.Precise temperature control and monitoring
31℃ ~ 37℃,7 levels adjustable. Applying high-sensitivity sensor and innovative intelligent dynamic control algorithm,which can accurately control the inhalation temperature of the patient end, and monitor it real-timely to ensure that the heating and humidification are safe and effective. The humidity can reach 100% to meet the needs of more patients.
3.Precise flow control and monitoring
Flow setting range: 2L / min ~ 80L / min, the imported flow sensor can ensure the accuracy of high-flow gas, and at the same time monitor the gas flow in real time to ensure the effective treatment of patients.
4.Optional blood oxygen module
The blood oxygen module can monitor the patient's blood oxygen saturation and pulse rate in real time, providing more treatment information for patients and medical staff.
Navigation