Model: CNME010426
Application:
Continuous Positive Airway Pressure (CPAP) nurtures and supports infant breathing by providing respiratory support throughout the respiratory cycle.
CPAP System maintains the infant's functional residual capacity by helping to prevent airway closure.
The CNME010426 CPAP System has the advantages of compact device, small footprint, saving energy and integrated high-performance in operation.This makes it an ideal companion for your smallest patients in the Neonatal Intensive Care Units (NICU), emergency ward, delivery room and other departments.
Feature:
7" TFT LCD screen displays the ventilation parameters, alarm information and oscillograms.
Integrated breathing circuit design, ensure easy operating and keep hygiene.
Multiple parameters monitoring interface ensures every parameter is clear, let operator know the patient conditions in all aspects.
Real time pressure-time oscillogram and high precision oxygen concentration detection function included.
Built-in air and oxygen blender, ensure stable oxygen concentration.
Stable and low noise air compressor creates quiet work environment for doctors and patients, able to support 2-3 CPAP machines at the same time.
Safety:
Three levels alarm system, visual and audible alarm information.
Different types of alarm, reminder and protection functions are available.
Advanced power management control technology.
Built-in backup battery provides the emergency power supply to the unit.
Technical Specification:
Parameter | Oxygen concentration: Adjusting range: 21% ~ 100% Monitoring range: 15% ~ 100% CPAP: Adjusting range: 0 cmH2O ~ 15 cmH2O Monitoring range: 0 cmH2O ~ 60 cmH2O Continuous flow: Adjusting range: 2 L/min ~ 20 L/min Monitoring range: 2L/min ~ 20 L/min Manual ventilation: Output flow: 20 L/min±5 L/min Air compressor: Continuous output flow: ≥25 L/min Peak output flow: ≥120 L/min Oscillogram: P-T (pressure-time) |
Alarm and protection | AC power failure alarm: Power failure or no connection Internal backup battery low voltage alarm<11.3±0.3V High oxygen concentration alarm: 19%~100% Low oxygen concentration alarm: 15%~99% High airway pressure alarm: 1.5kPa~6kPa Low air input pressure alarm: < 200 kPa Low oxygen input pressure alarm: < 200 kPa Air and oxygen blender alarm: When any gas source lack When differential pressure: > 0.1mPa Compression pump alarm: Excess temperature |
Size | Main engine: L480*W670*H450 mm G.W..40 KG, NW.: 23 KG Air compressor: L683*W687* H1140 mm G.W. : 105 KG N.W. : 70 KG |