Get Quotes
Download Full Catalogue
Model: CNME010421
Application:
The ventilator makes a good performance in operation room,ICU department and emergency treatment. It used to assist or replace the spontaneous breathing for adult pediatric and neonatal more than 2kg. Due to the flexible configuration, good quality and competitive price, CNME010421 has soon become the superstar of market.
Features:
15* TFT touch screen displays the ventilation parameters, alarm information, and oscillograms, make every operation more easily.
Multiple ventilation modes, suitable for ICU, emergency department and operation room etc: ( IPPV, AC, PCV, SIMV, PSV, SPONT/CPAP, SIGH, MANUAL)
5 oscillograms for your choice, 3 of them can be displayed on the screen at the same time.
Humidifier can heat and wet breathing gas, makes it comfortable for patient to breathe.
Rapid oxygen supply, automatically offer high flow rate oxygen within two minutes
Nebulization make medicine into small liquid and particle, easier and quickier for patient to breathe in.
High temperature resistance breathing circuit is reusable and antipollution.
Safety:
14 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
Built-in oxygen concentration sensor, ensure stable precision of oxygen concentration.
Easy to move with four casters, easy to stop with two brakes.
Separate design of electronic circuit and gas flow rate keep safe running of ventilator.
Compact long life internal battery can provide emergency power, avoid risk of patient
Self-check before operation, eliminate system mistake.
Technical Specification:
Ventilation Mode | PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV, IPPV, A/C, PCV, PSV, SPONT/CPAP, SIGH, MANUAL |
Ventilator parameter | Tidal volume (Vt): 20 ~ 2000 mL Frequency (Freq): 1min~100min Oxygen concentration: 21%~100% I:E: 4:1~1:8 PEEP: 0cmH2O ~ 40 cmH2O Pressure triggering sensitivity(Ptr): -20 cmH2O ~ 20 cmHO (Based on PEEP) Flow trigger sensitivity (Ftr): 0.5L/min~ 30 L/min Pressure control (PC): 5 cmH2O ~ 80 cmH2O Pressure support (PS): 0 cmH2O ~ 80 cmH2O SIGH: 0 (off) 1/100 ~ 5/100 Apnea ventilation: OFF, 5s~60s, Pressure limit: 20 cmH2O ~ 100 cmH2O |
Monitoring parameter | Frequency (Freq): 0/ min~ 100/ min Tidal volume(Vt): 0mL~2500mL MV: 0 L/min ~ 99 L/min Airway pressure: 0 cmH2O ~ 100 cmH2O Dynamic lung compliance testing: 1 mL/cmH2O ~ 1000 mL /cmH2O Oxygen concentration: 15%~100% |
Packing size | Main components: L 560* W 560 * H 605 mm G.W. :40KG, N.W.: 17 KG Air compressor: L 670* W 700 * H 1160 mm G.W. : 84 KG, N.W. : 46.2 KG |
Alarm and protection | AC power failure alarm: Power failure or no connection Internal backup battery low voltage alarm≤11.3±0.3V No tidal volume: No tidal volume within 6 s High minute volume alarm: 5 L/min ~ 99 L/min Low minute volume alarm: 1 L/min~ 30 L/min High airway pressure alarm: 20 cmH2O ~ 100 cmH2O Low airway pressure alarm: 0 cmH2O ~ 20 cmH2O High oxygen concentration alarm: 19%~100% Low oxygen concentration alarm: 18%~99% Continuous pressure alarm: (PEEP+ 1.5 cmH2O)over16s Suffocation warning: 5~ 60s Fan error: Show on screen Oxygen deficit: Show on screen The maximum limited pressure: <12.5kPa |
Working condition | Gas source: O2, Air Pressure: 280 kPa- 600 kPa Voltage: 220V±22V Power frequency: 50Hz±1 Hz Input power: 900 VA (With air compressor) 250 VA (Without air compressor) |
Oscillogram | P-T(Pressure-Time) F-T(Flow-Time) V-T(Volume-Time) P-V Loop(Pressure-Volume Loop) F-V Loop(Flow-Volume Loop) P-F Loop(Pressure- Flow Loop) |
Navigation