Model: CNME010401
Technical Specification:
Ventilation Modes | VCV(A/C) PCV(A/C) PRVC SIMVIVCV)+PSV SIMV(POV)+PSV SIMV(PRVC)+PSV SPONT/CPAP+PSV BIVENT+PSV NIV/CPAP NIV-T NIV-S/T |
Parameters | Tidal Volume: 20-2000 ml Respiration Rate: 1-80 bpm Tinsp: 0.2~9 s Tslope: 0-2 s Tpause: 0~4 s I:E Ratio: 1:10-4:1 FiO2: 21 %~100% Trigger Sensitivity: Pressure (-20~0 cmH2O, above PEEP) Flow (0.5~20 LPM) PEEP: 0~35 omH2O Psupport: 0~70 omH2O Pinsp: 5~70 omH2O |
Special Procedures | Apnea Ventilation Smart Suction Manual Breath Insp/ Exp Hold ETCO2 Measurement Nebulization Waveform Freeze |
Monitoring | Pressure Value: Ppeak, Pplat, Pmean, Pmin, PEEP Volume / Flow Value: Vti, Vte, MV, MVspont Time Value: ftotal, fspont, l:E Real Time Curves: Pressure-Time, Flow-Time, Volume-Time waveforms Pressure-Volume, Volume-Flow, Flow-Pressure loops Gas Monitoring: FiO2, ETCO2 Calculated Values: Compliance(C) Resistance(B) MVleak RSBI WOB PEEPi |
Alarm | Paw high/low MVe high/low Circuit disconnection FiO2 high/low Inspiration/Expiratory tidal volume low High Respiration Rate Apnea AC Failure Nebulizer On Low Battery Air/O2 supply down High/Low PEEP Leakage out of range Occlusion |
Technical Data | Screen: 12”TFT color touch screen (detachable) Supply Gas: O2, 0.28~0.6 MPa Power Supply: AC100~240 V, 50 Hz/60 Hz Communication Interface: RS-232 Port, Nurse call Port, Ethernet Port Dimension (WxDxH): 322 mm x 375 mm x 366 mm (Main Unit) 547mmx675mmx950mm(Cart) Weight: 12.5 kg (Main Unit) 25 kg (Cart) |
Superior Mobile ICU ventilator
Comprehensive ICU ventilator including BIVENT and PRVC
Compact, big capacity battery, no air compressor, intra-hospital mobility
Flexible device configuration: equipped on a trolley, bed or ceiling pendant
Cost Effective Solution
Unique metal-based, autoclaved, heated exhalation valve
Built-in flow sensor, non-consumable design
Upgradeable ventilation system software, with an available USB port
Safe Ventilation Through Whole Treatment Phase
Initial Treatment Phase
Noninvasive ventilation mode associated with decrease incubation rates, shortened patient stays, improved patient comfort, and a reduced risk of cross infection
Preset patient's height and IBW. Reduce clinician's workload
Stable Condition Phase
PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation
Comprehensive lung mechanics monitoring include compliance, airway resistance, PEEPi and time constant
Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient's condition
Weaning Phase
Various ventilation modes enhance the weaning process
The unique trigger and leakage compensation system safeguards each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery
RSBI and WOB provide accurate reference for weaning
Rehab Phase
Data export port provides connection to hospital monitors and Patient Data Management Systems
Provides pressure support for the patient when spontaneous breathing is present
An Optimal Combination of Invasive and Noninvasive Ventilator
As noninvasive ventilation is used increasingly in a wide range of clinical situations, we offer a dual solution
CNME010401 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU
Optimal patient-ventilator synchrony, increase patient comfort
The Unique Leak Compensation System - Keep precise control on the tidal volume of each breath
delivered to the patient by adjusting compensation dosage automatically
Advanced Trigger Technique - Enhance sensitivity, avoid spurious triggering
Auto-detect and Adjust Leak Compensation
Automatically, Adapt to Patient’s Breathing Pattern
Multi-parameter Monitoring